Delta Ridge Technologies · power
A system that supplies its own controls and auxiliaries from a tap on its own source, then delivers the rest to the house. Choose the source, put in your real numbers, and this sizes the machine, the storage and the inverter. Nothing here is a closed loop that runs on itself: the energy always comes from water, sun, or fuel, and the machine keeps itself alive from a small share of what it makes.
What each household size actually requires, at 60 percent water system efficiency and 4.8 peak sun hours.
| Load | Average W | Water at 5 m | Water at 8 m | Water at 12 m | Solar array | Battery |
|---|
| Part | Rating to buy | Why |
|---|---|---|
| Intake and penstock | bore sized for under 1.5 m/s, screened, with a settling box | head lost in the pipe is power you never see |
| Turbine | Pelton for 20 m and up at low flow, crossflow or Kaplan for 2 to 10 m at high flow | match the runner to head and flow, not the other way round |
| Generator | permanent magnet, 48 V, sized 1.3x the continuous power | PMG rectifies to DC with no excitation circuit to fail |
| Charge controller | MPPT, 48 V, 20 percent headroom on current | keeps the alternator on its best power point |
| Battery | LiFePO4, 48 V, nameplate sized by the autonomy days | this is what runs the controls before and after generation |
| Inverter | 48 V hybrid, continuous above peak load, 2x surge | supplies the house and passes generator power through |
| Dump load | resistive element plus controller | absorbs surplus when the battery is full and load is light |
| Safety | DC breakers, ground fault, conduit, earth electrode | 48 V DC arcs and wet ground are the real hazards here |
Sizing rule of thumb: generation should exceed daily use by about 25 percent so a bad day does not drain the bank, and the battery should cover autonomy days at 90 percent usable depth for lithium.
The machine's own controls, inverter and any feed pump draw from a tap ahead of the house. At 35 W idle that is under one unit a day, which generation covers many times over. What no design can do is supply its own prime mover: a generator spinning another generator that spins the first has friction, copper loss and bearing drag in the loop, and the loop always decays. The self-sufficiency comes from the water or the sun being free, not from the machine paying itself.